go to top scroll for more

Projects


Projects: Projects for Investigator
Reference Number NIA_NGET0046
Title Flexible rating options for DC operation
Status Completed
Energy Categories Other Power and Storage Technologies(Electricity transmission and distribution) 100%;
Research Types Applied Research and Development 100%
Science and Technology Fields ENGINEERING AND TECHNOLOGY (Electrical and Electronic Engineering) 100%
UKERC Cross Cutting Characterisation Not Cross-cutting 100%
Principal Investigator Project Contact
No email address given
National Grid Electricity Transmission
Award Type Network Innovation Allowance
Funding Source Ofgem
Start Date 01 January 2012
End Date 01 April 2015
Duration 39 months
Total Grant Value £245,000
Industrial Sectors Power
Region London
Programme Network Innovation Allowance
 
Investigators Principal Investigator Project Contact , National Grid Electricity Transmission (100.000%)
Web Site http://www.smarternetworks.org/project/NIA_NGET0046
Objectives To develop tools for the rating and technical assessment of high power HVDC cable options. The work will initially concentrate on cables with mass impregnated insulation. To provide National Grid with techniques to evaluate continuous, transient and dynamic (real time) ratings for DC cable circuits and to evaluate the options and limits for features such as current dependent voltage control. Development of a tool for rating and technical assessment of high power HVDC cable options.
Abstract The calculation of current ratings for DC cable is significantly more complex than that for AC cable. The rating is often determined by electric stress constraints rather than considerations of thermal ageing. Ratings are also strongly influenced by thermally induced pressure transients within the cable. In some cases the rating of the cable can be restricted by the cable being too cold. As the normal operating voltage of the cable increases the cable can experience high levels of electric stress while the cable is hot. As the cable cools it is susceptible to electrical failure. Some manufacturers require the converter station to reduce its operating voltage if the current on the link is reduced. The implementation of these current dependent voltage control systems may help protect the cable, but this approach does not align well with the concise cable rating sheet used as part of the CUP package. This introduces an additional level of complexity for Network Operations. The method that has been proposed for this project includes: Initial review of the modelling techniques and materials parameters applicable to HVDC cable ratings Interim report on algorithm development for thermal rating of MI cables Interim report on algorithm development for steady state modelling of electric in non-linear insulating materials Report on temperature and electric field modelling for rating MI cablesNote : Project Documents may be available via the ENA Smarter Networks Portal using the Website link above
Publications (none)
Final Report (none)
Added to Database 14/08/18